By Suman Pathak
Posted 2 years ago

Basic of MEP

General

Share
banner image

 

Basic of MEP

MEP, or mechanical, electrical, and plumbing engineering, are the three technical disciplines that encompass the systems that allow stations/building interiors to be suitable for human use and occupancy. MEP construction must require all types of commercial, residential, and industrial purposes where services and facilities are required.


MEP consists of installing air conditioning systems, water supply & drainage systems, firefighting systems, electrical power, and lighting systems including transformer substations and emergency power generators, fire protection and alarm systems, voice & data systems, security access, and surveillance systems, UPS, public address systems, Mast antenna TV system, and building management systems.

MECHANICAL WORKS IN MEP PROJECT

In MEP, major works are to be handled by Mechanical people because of HVAC or air conditioning system and that has piping work for cold and hot water, fabrication works for ducts, dampers and controllers, thermal/cold insulation works, and erection of machines like chiller unit, air handling units, grills, diffusers, etc. along with works of Drinking water, Drainage, and Sewerage systems. Other important Mechanical works are Firefighting works that included piping, sprinklers, and Pumps.

ELECTRIC WORKS IN MEP PROJECT

Electric works mainly included Electrical Power and Lighting but others like Transformer substations, Emergency power, UPS/Central battery, Voice/Data communication, TV, Security systems like CCTV surveillance system, Access control System, Public address system, Building management system (BMS), Fire alarm system, Surge Protection system, and Lightning protection system.

PLUMBING WORKS ON MEP PROJECT


Plumbing is a system of pipes and fixtures installed for the distribution and use of potable (drinkable) water, and the removal of waterborne wastes. It is usually distinguished from water and sewage systems that serve a group of buildings or a city.

To continue reading Register Now or Login

Suggested Articles for you

Jyoti TV - Posted 2 years ago

Have a job interview coming up? Pre-interview preparation Step

    Are you getting ready for a job interview?  A practice run can provide you with the necessary preparation to ace the real thing. A quick read-through of the Article published in RailFactor may also help you. Your success in a job interview is heavily reliant on how well you prepare for it. Interview preparation primarily entails researching the job and the company, as well as carefully considering your responses to interview questions. Listed 5 Pre-interview preparation Steps which may help to grab your dream job. PRE-INTERVIEW PREPARATION - STEPS TO GET YOUR DREAM JOB Review the job description Review the keywords and key phrases in job description Refresh your skills and add certification Are you eligibile Ask the questions. Am I right fit. Why the employer should hire you.  Know the company Find out vision, mission, management, work culture and types of products/service.  Prepare a list of expected interview questions Tell me about yourself. Why are looking for a job change? What are your strengths and weaknesses? Update your social media profile Employers may look at your social media presence to get a sense of your personality and history.

Read Full Article

Suman Pathak - Posted 2 years ago

Earthing works in Railway building/Metro Stations or Substation

MAJOR PARTS OF E&M WORKS IN RAILWAY BUILDING/METRO STATION OR SUBSTATION CONSTRUCTION 1.    Earthing 2.    Conduiting 3.    Light Point wiring, Power Point 4.    Installation, testing, commissioning of light fixtures 5.    laying of cables, jointing, termination etc. 6.    laying of Cable Tray, HDPE pipe. RCC pipe Let’s get a short brief about all one by one EARTHING The earthing protection is an integral part of any electrical system and is required to  a.    Protect personnel and equipment from electrical hazards. b.    Achieve a reduction in potential to the system neutrals. c.    Reduce or eliminate the effects of electrostatic and electromagnetic interference on the signaling and Telecom equipment arising from auxiliary electrical systems. The main purpose of earthing in the electrical network is for safety.  i)    When all metallic parts in electrical equipment are grounded then if the insulation inside the equipment fails there are no dangerous voltages present in the equipment case.  ii)    To maintain the voltage at any part of an electrical system at a known value to prevent over current or excessive voltage on the appliances or equipment.  iii)    Lightning, line surges, or unintentional contact with higher voltage lines can cause dangerously high voltages to the electrical distribution system.  The earthing is broadly divided as a)    System earthing (Connection between a part of a plant in an operating system like LV neutral of a Power Transformer winding and earth). b)    Equipment earthing (like motor body, Transformer tank, Switch gearbox, Operating rods of Air brake switches, etc.) to earth. Earthing provides an alternative path around the electrical system to minimize damages in the system.  There are several types of earthing systems such as Earth Mat, Plate Earthing & Pipe Earthing which could be used in an elevated station and Substations.  The selection of earthing depends upon several factors such as: i)    Availability of Land ii)    Type of Soil iii)    Resistivity of Soil Mainly we follow two Specifications for earthing I.    IS:3043 II.    IEEE 80 The most commonly used earthing method is Earthmat or Grid  Earth Mat or Grid The primary requirement of Earthing is to have a low earth resistance.   Substation involves many Earthlings through individual Electrodes, which will have high resistance.  But if these individual electrodes are interlinked inside the soil, it increases the area in contact with soil and creates a number of parallel paths.  Hence the value of the earth resistance in the inter-linked state which is called combined earth value which will be much lower than the individual value. The interlink is made through a flat or rod conductor which is called an Earth Mat or Grid.  It keeps the surface of substation equipment as nearly as absolute earth potential as possible.                                                                                             Picture: Earthmat  To achieve the primary requirement of Earthing system, the Earth Mat should be designed properly by considering the safe limit of Step Potential, Touch Potential, and Transfer Potential. The factors which influence the Earth Mat design are: a.    Magnitude of Fault Current b.    Duration of Fault c.    Soil Resistivity d.    The resistivity of Surface Material e.    Shock Duration f.    Material of Earth Mat Conductor g.    Earthing Mat Geometry Step Potential It is the potential difference available between the legs while standing on the ground. When a fault occurs at a tower or substation, the current will enter the earth. Based on the distribution of varying resistivity in the soil (typically, a horizontally layered soil is assumed) a corresponding voltage distribution will occur. The voltage drops in the soil surrounding the grounding system can present hazards for personnel standing in the vicinity of the grounding system. Personnel “stepping” in the direction of the voltage, gradient could be subjected to hazardous voltages Touch Potential Touch potential is the voltage between any two points on a person’s body – hand to hand, shoulder to back, elbow to hip, hand to foot, and so on. The touch potential or touch voltage could be nearly the full voltage across the grounded object if that object is grounded at a point remote from the place where the person is in contact with it .       The earth resistance shall be as low as possible and shall not exceed the following limits: EHT Substations    -    1.0 Ohms 33KV Stations        -    2.0 Ohms Metro Stations    -    < 1.0 Ohms Specification of Earthing Depending on soil resistivity, the earth conductor (flats) shall be buried at the following depths.             Soil Resistivity in ohms/metre     Economical depth of Burial in metres                                                                      1)        50 – 100                                              0.5                                                                       2)       100 – 400                                            1.0                                                                       3)        400 – 1000                                         1.5 To keep the earth resistance as low as possible to achieve safe step and touch voltages, an earth mat shall be buried at the above depths below ground and the mat shall be provided with grounding rods at suitable points. All non-current carrying parts at the Substation shall be connected to this grid to ensure that under fault conditions, none of these parts are at a higher potential than the grounding grid.      

Read Full Article

Nabayan Datta - Posted one year ago

Long Trains in IR - History & Significance

A key difference between rail transport system and all other inland transport systems is the carrying capacity per consignment. Which is very much for a freight train. A single freight train is capable of transporting an average of 4000 tonnes of goods in a single consignment, in a 59 unit train. So one of the reasons for thie greater reliability of the people of the country towards this railway system in internal trade is the size of the railway cars. The term long train has two different meanings in the railway system, 1. Length of a rake according to wagons 2. Length of a train according to rakes. I will share something in my simple language how railways can haul more tonnage to their customers in shortest time by increasing train length. Length of a rake Per unit:- As mentioned earlier, thing that makes rail superior to road and air freight transport is that a single. By consignment, the amount of goods that a train can deliver to its destination is relatively less than the other two. Transporting large quantities of goods in a single consignment requires wagons with higher carrying capacity and rakes consisting of a larger number of wagons. New Delhi, Railway Board cited two reasons why a train can have maximum number of wagons? As stated as the main reason, the number of wagons of a rake is limited by the Loop length and Ruling Gradient of the moving section. And, as a secondary factor, the train load of each wagon is divided between the wagons and the nature and demand of the goods transported in those wagons. For example, BCN trains can have at most 43 wagons in total, BOXN trains can have at most 59 wagons. One thing has been proved in the matter that since BOXN wagons carries raw coal, it is natural that the number of wagons in that rake is more than all the others and in fact the number of wagons of BOXN is more than all the others. Because, there is no need to repeat how essential coal is to civilization. Correspondingly, loop lines in Indian Railways are sized according to the size of a 59 BOXN + 2 Loco and not all stations in any division are capable of accommodating such lenght, especially those stations whose layouts are somewhat outdated. Length of a train per rake:- 3rd March, 2011 On the recommendation of the Senior Divisional Operation Manager of Allahabad Division, a committee called 'Recommendation Committee for long haul operation' was formed with all the COMs and engineers of the country. A groundbreaking decision was taken that, like the railways of all the developed countries of the world like the USA and Australian railways, the freight business will be developed here by forming and running long haul trains. At that time, all the railways of the country, except Eastern Railway, North Eastern Frontier Railway and East Central Railway, started running these long haul trains on trial basis and 25 Nos. of long haul train were run per day across the country. Then there are two plans from the traffic, mechanical and electrical branches of the rail board about when and how the train will be formed, 1. Short term and 2. Long term plans and set some rules regarding them. Short term 1.These trains can be formed only from some specified stations. 2. Inspite of having separate BPC for each rake, a separate type of BPC has to be issued for the entire train, which we know as Cover BPC. 3. In that BPC, it will be stated at which station the long haul formation will be broken and it will also be said that if any emergency situation occurs somewhere in the middle, it can be broken at any station. 4. If you want to make a long haul train, you have to keep some points in mind regarding the arrangement of rakes and engines, such as: if you want to make a long haul train with loaded and empty rakes, keep the loaded rake in front, empty one after it, then loaded again, then empty again. These must be arranged in formation. Regarding locomotives of long haul trains, front locomotives can do Air pressure creation, Braking and Tractive effort but rear locomotives can do nothing except Tractive effort and emergency braking. Long term 1. In the case of long haul train formation, the optional use of Twin pipe rake, it increases the pressure very quickly and easily, which is very essential in a long train like long haul. 2. Modern DPWCS (for electric locos) and DPCS (for diesel locos)) will be used for improved communication between locomotives. 3. Construction of Long Loop lines of more than 1 km in the distance of 50 km on each of the busiest routes of the country in the next few years, so that the momentum of the passenger train is not hindered for the continuous movement of the long haul train. Correspondingly, the country's longest long haul train so far is made up with 3 BOXNS and 2 BOXNHL rake and is 3.5 km long, weighed 27000t. approx which was amalgamated by Bilaspur Division of South East Central Railway and named it 'Super Vasuki'. The train run continuously from Korba to Rajnandgaon. Also, WDFC division of DFCR zone of the country is running the first double stack container train as long haul in the country. Means, 2 trains are running together but due to double layer stacking, load is carried by 4 trains. This success of DFCR has left a response among the railway companies all over the world and we should be proud to hear that, the management of this consist has been proven better than the freight management of American railway companies and Chinese railway companies. Also, now each zonal division is making long haul trains and covering short kilometers on a daily basis. Needfulness   So, what is the need of running long haul goods train? After running all these long haul trains in the Indian railway system, many people applauded, but some people did not stop criticizing the matter. I have seen those criticisms in many places on social media, and I think the two criticisms made by them are important.  1. How such type of running save the normal transit time of any consignment? i don't think so it works. 2. It will create sectional congestion and bunched the coaching traffic. I am trying to answer these two critics as much as I can and understand as much as I can. First of all, you need to know what internal factors are involved in the transit time of a consignment. From loading to unloading, many events take place. I will talk about two factors in it. The first factor that comes to mind is:- Ordering of Train: - From rake loading to rake release crew ordering is given accordingly by making an accurate pre-estimate of the departure of the train based on crew availability, path availability and power availability. The accuracy of that depends on the TT loss of that train. Total time of crew on run:- How long does a crew stay running on that train and how far do they take that train in their 8 hour/10 hour duty period? These two are key indicators regarding TT of Consignment. Because, the TT of consignment does not depend on what the crew is doing outside the running hours during their duty period or how little they are in the running state. What are the reasons for their maximum output being hindered during the duty period? Two reasons can be identified:-                                1. Procedural Obstacles:- It has been said in a JPO of the Railway Board that before starting from an originating station or a station where the rake is stable for more than 24 hours, the Mainline crew must check the entire train along with the Guard. It consumes 45 minutes to 1 hour of his duty period.                 2. Operational constraints:- Several pre-planned crew changing stations are defined within each division. Means, Crew has to drop from whichever direction the train is coming and the next crew takes charge of that train and sometimes the train even cannot covered 100 km in 10-12 hours. There are also many other unavoidable reasons such as, Sectional congestion, Traffic Block, Accident, Rail roko etc. But to overcome the above two avoidable reasons and decrease TT as much as possible, Railways have started an incredible approach by running multiple trains in the same direction simultaneously by amalgamating each other, without changing crew midway in that direction, continuously up to a nominated marshalling yard. As a result, Crew saving is done, TT of more consignments is saved a lot. Thus if more than one division can operate in this manner in the total journey of the consignment little by little, TT will save a lot. If someone asks how it will be benefited to run multiple train coupled with each other instead of running separately? Let's say there is a pre-planned departure of 2 goods trains from Anara station of South Eastern Railway towards Andal after crew change. One is BOXN/STAR and the other is BOXN/PACT. BOXN/STAR is almost ready to leave Annara and BOXN/PACT is entering Anara. This time, if two trains of the same direction are run separately and not together, then it may take several hours to arrange the crew separately for the train that entered later and prepare the car for departure. This time there may be several other trains between when it is ready and when it leaves BOXN/STAR. As a result, due to not getting the path at the right margin, BOXN/PACT may have to stand for a long time even after being ready. Because, to run a through goods train with proper momentum, it is necessary to get line clear from multiple stations before it. So if BOXN/STAR and BOXN/PACT are run together, the above problems can be overcome. Because, if two trains are joined together then it becomes high priority train. As a loop line of sufficient length is not available to catch it in the middle, it can be brought to the next nominated station by pulling it. It will save the transit time of two cars and if the number of long haul trains is slowly increased by this practice, the sectional congestion will also decrease, as a result, other traffic can be brought down in that section. The answer to the second criticism can be found in the above analysis!  

Read Full Article